Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Cardiothorac Surg ; 19(1): 14, 2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38245799

RESUMEN

OBJECTIVES: The management for pneumothorax patients involves surgical intervention, nevertheless postoperative recurrences are often encountered. To reduce the rates of recurrence, thoracic surgeons have experimented with various novel techniques, such as pleural abrasion, chemical pleurodesis, and staple line coverage with absorbable sheets, in addition to bullectomy. And in recent years, there have been reports of the effectiveness of the use of intraoperative glucose intrapleural spray (GIS) containing 50 ml of 50% glucose solution in addition to bullectomy. However, information on the effects and adverse events of GIS is limited. Current study was aimed to assess the efficacy and safety of GIS in preventing recurrence of pneumothorax. PATIENTS AND METHODS: We conducted a retrospective study with 74 cases of bullectomy with or without GIS between 2018 and 2021 at Okazaki City Hospital. Of these cases, 50 received GIS (GIS group) while 24 were treated conservatively (C group). RESULT: The GIS group consisted of 46 males and 4 females, whereas the C group consisted of 23 males and 1 female, with mean ages of 38.5 ± 5.7 years and 30.5 ± 6.7 years, respectively. The GIS group exhibited a mean increase in blood glucose of 23.8 mg/dL postoperatively, and postoperative infections were observed in 2 cases in the GIS group (4.0%) and 2 cases in the C group (8.3%). The NRS scores of the patients in the GIS group and the C group three hours postoperatively were 4.0 and 3.1, respectively (p = 0.28). No prolongation of postoperative drainage period by GIS was observed (1.2 days and 1.4 days in the GIS and C groups, respectively). Postoperative recurrence occurred in two patients from the C group. The postoperative total drainage volumes were 341.8 ± 25.2 ml and 74.2 ± 25.5 ml in the GIS and C groups, respectively, showing a significant increase in drainage volume (p < 0.01). None of them presented dehydration-related symptoms. CONCLUSIONS: The use of intraoperative glucose intrapleural spray is effective and safe in terms of preventing recurrences and postoperative complications.


Asunto(s)
Neumotórax , Masculino , Humanos , Femenino , Adulto , Neumotórax/terapia , Glucosa/uso terapéutico , Estudios Retrospectivos , Pleurodesia/métodos , Cirugía Torácica Asistida por Video/métodos , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Recurrencia , Resultado del Tratamiento
2.
Asian Cardiovasc Thorac Ann ; 30(7): 859-861, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35603627

RESUMEN

Xiphoid syndrome is a rare musculoskeletal disorder of the xiphoid process. The main symptom is precordial pain or xiphodynia. We experienced a case in which protrusion of the xiphoid process impaired blood flow to the skin, resulting in the formation of an ulcer and exposure of the xiphoid process. To the best of our knowledge, this is the first case of a xiphisternal ulcer secondary to a protruding xiphoid process. The patient was safely and effectively treated via xiphoidectomy using a T-saw.


Asunto(s)
Enfermedades Musculoesqueléticas , Apófisis Xifoides , Dolor en el Pecho , Humanos , Enfermedades Raras , Resultado del Tratamiento , Úlcera
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...